From Simulation to
Real-World Operation
Centre of innovative solutions where concepts become reality. We implement projects verified through simulations and fully tailored to the individual requirements of each customer. Get a BESS quote
REDOX BESS
Flow batteries represent an innovative energy storage solution.
Learn moreLAB EQUIPMENT
Testing equipment for battery stacks – kW Test Rig, Air Test Rig.
Learn moreAI EMS AORTA+
Smart energy management built on real-world models and technologies
Learn moreDIGI TWIN
Simulation and optimization of energy systems before deployment.
Learn moreLFP BESS INTEGRATION
Battery storage integration for efficient energy utilization.
Learn morePCS INTEGRATION
Integration of power conversion systems into functional energy solutions.
Learn moreEPCm SERVICES
Comprehensive engineering, construction, grid integration, and commissioning.
Learn moreSERVICE & SUPPORT
Consulting and servicing of energy solutions at the highest level.
Learn moreAbout Us
We combine technology, vision, and confidence in the future of energy.
We are a team of experts delivering innovative solutions in energy systems, battery storage technologies, and digital energy management.
Our goal is to help companies and organizations use energy more efficiently, safely, and economically.
We rely on years of experience in business, technology, and energy system implementation, enabling us to connect state-of-the-art technologies with real customer needs.
References
Prečo práve InoHub ?
Vízia
Energetika budúcnosti musí byť inteligentná, flexibilná a ekonomicky udržateľná. Naša vízia spája technológiu, dátové modelovanie a prax, aby podniky získali skutočnú energetickú autonómiu.
Inovácie
Prinášame riešenia, ktoré vychádzajú z aplikovaného vývoja, AI modelov a digitálnych dvojčiat. Neustále posúvame hranice BESS technológií a riadenia energie.
Spoľahlivosť
Od návrhu až po prevádzku poskytujeme technológie s vysokou dostupnosťou, stabilným výkonom a dlhodobou podporou. Naša priorita je prevádzková istota klienta.
Efektivita
Každý projekt navrhujeme tak, aby prinášal merateľné úspory a maximálnu energetickú účinnosť. Zvyšujeme výkon, znižujeme straty a optimalizujeme životný cyklus úložiskových systémov.
Odbornosť
Opierame sa o technickú kvalitu overenú nezávislými skúškami. Spolupracujeme s autoritami ako TÜV SÜD, aby boli naše riešenia bezpečné, certifikované a profesionálne integrované.
Ekonomickosť
Naše riešenia dávajú ekonomický zmysel. Kombinujeme BESS, AI riadenie a energetické modelovanie tak, aby klient dosiahol rýchlejšiu návratnosť, stabilné cash flow a dlhodobé zníženie nákladov.
LIVE Stream
Battery Status
Basic Metrics
Cycles Cumulative
0
Active Power AC
0 kW
Discharged Energy (Last cycle)
0 kWh
Outside air temperature
0°C
Battery Degradation
0.00%
• Maximal DC power of battery is 72 kW
• Maximal stored energy for both modules is 80 kWh
• Typical cycle SOC range is 15% to 85%
• Cycles cumulative represent total number of cycles of both modules from 27.6.2025
• SOC represents average SOC level of both modules
• Active power AC represents total power of both modules
• Discharged energy represents DC energy discharged from Module 2 during one standard cycle
• Electrolyte temperature represents average value from both tanks for anolyte and catholyte
• Battery degradation is calculated from initial value of Module 2 after every 50–70 cycles of operation
The information published on this website, information about products, services and activities of INO-HUB Energy j.s.a. (including technical data and parameters of battery prototypes) is for informational purposes only and is not legally binding; INO-HUB Energy j.s.a. does not warrant its accuracy, completeness, reliability, applicability or timeliness, does not assume any warranty (including warranties of merchantability, non-infringement and suitability for a particular purpose), no obligation or liability with respect thereto, and shall not be liable for any damages or other loss resulting from the use of this information by any third party. The information may be changed or updated without notice.
Power and Temperature - History - 24 hours
Battery Degradation Comparison
Current Battery Status
Compare the degradation rates of Redox Flow Battery vs LFP (LiFePO4) Battery under the same load conditions:
System Images
Power and Temperature - History
Vanadium electrolyte is not consumed — it can be reused at the end of the system’s service life.
energy discharged in the last cycle —
electrolyte, average —
ambient temperature —
Technical conditions and legal notice
Specifications and measurement method
- The maximum DC power of the battery is 72 kW.
- The maximum stored energy of both modules combined is 80 kWh.
- The typical cycling range is 15% to 85% SOC.
- The cumulative cycle count is the total number of cycles across both modules since 27 June 2025.
- The SOC in the header is the average state of charge of both modules; the module cards show the SOC of each module separately.
- AC active power is the total power of both modules.
- Discharged energy is the DC energy discharged from module 2 during one standard cycle.
- Electrolyte temperature is the average across both tanks for anolyte and catholyte.
- Battery degradation is calculated relative to the initial value for module 2 after every 50–70 operating cycles.
About this visualization
- The electrolyte color is a visual representation of the state of charge based on vanadium oxidation states, not a measurement of the liquid’s color.
- The liquid level in the tanks is constant — in a flow battery, the level does not change; the electrolyte simply circulates.
- The LFP curve is a model based on published lifetime data for lithium iron phosphate cells, not a measurement.
- If the device does not respond, the dashboard displays demo data and clearly labels it as such.
The information published on this website, information about products, services and activities of INO-HUB Energy j.s.a. (including technical data and parameters of battery prototypes) is for informational purposes only and is not legally binding; INO-HUB Energy j.s.a. does not warrant its accuracy, completeness, reliability, applicability or timeliness, does not assume any warranty (including warranties of merchantability, non-infringement and suitability for a particular purpose), no obligation or liability with respect thereto, and shall not be liable for any damages or other loss resulting from the use of this information by any third party. The information may be changed or updated without notice.
News
INO-HUB Energy AS AN EXHIBITOR AT THE STARTER E EUROPE
EVALUATION OF FELT ELECTRODES AT LABORATORY CONDITIONS
INO-HUB Energy AS AN EXHIBITOR AT THE INTERNATIONAL FLOW BATTERY FORUM 2026
CONNECTING SIMULATION AND REALITY: AORTA+ AND DigiTwin IN PRACTICE
DigiTwin – DIGITAL TWIN AS THE BASIS FOR SAFE INNOVATION
AORTA+ : NEW GENERATION SMART ENERGY MANAGEMENT